ERBE VIO 300 D - Electrosurgery Unit

Description

ERBE has set an innovative standard with its new VIO electrosurgical system which provides optimal support for operative procedures in virtually all medical fields. And many more indications can be included. With the VIO 300 D generator module, a high-end unit, for the first time in electrosurgery ERBE offers automatic output dosage for all regulative Technologies: - voltage regulation for...

Full description

Technical Specifications

- All currently available electrosurgical regulative technologies in a single unit – with automatic output dosage;
- New and improved CUT and COAG functions;
- Can be individually configured to meet the requirements of different medical specialties, indications and procedures;
- Simple, interactive and safe operation using the TFT display and FocusView: Information is reduced to the essential;
- Individually configurable programs in simple text: switch on the unit and begin working;
- ReMode function: “remote control” via the handle or foot switch straight from the sterile field;
- Modular concept with APC 2, VEM 2, EIP 2, IES 2
- Maximum Cut output 300 Watt at 500 Ohm (with PPS temporary 400 Watt)
- Maximum Coag output up to 200 Watt
- Safety system NESSY
- Frequency 350 kHz
- Supply voltage 100 V – 120 V/220 V – 240 V ± 10 %
- Frequency 50/60 Hz
- Mains current max. 8 A /4 A
- Power input during stand-by 40 Watt
- Power input during max. electrosurgical output 500 Watt/920 VA
- Potential equalization connection yes
- Fuse T 8 A /T 4 A
- Width x Height x Depth 410 x 160 x 370 mm
- Weight 9,5 kg
- Ambient temperature for the transport and storage of the unit –40 °C until + 70 °C
- Relative humidity 10 % – 95 %
- Ambient temperature during operation of the unit +10 °C bis + 40 °C
- Relative humidity 15 % – 80 %
- Classification acc. to the EC-Directive 93/42/EE II b
- Protective class acc. to EN 60 601-1 I
- Type acc. to EN 60 601-1 CF 

Partner

ERBE VIO 300 D - Electrosurgery Unit

ERBE has set an innovative standard with its new VIO electrosurgical system which provides optimal support for operative procedures in virtually all medical fields. And many more indications can be included. With the VIO 300 D generator module, a high-end unit, for the first time in electrosurgery ERBE offers automatic output dosage for all regulative Technologies: - voltage regulation for sparing, reproducible cutting and coagulation - arcing regulation in for high-energy cutting and coagulation and for cutting under water - output regulation to maintain constant power levels during coagulation and devitalization We configure the VIO 300 D both the hardware and the software according to the medical specialty, the indication and the specific requirements of the operative procedures. This means that operative interventions can be carried out even more efficiently, precisely and sparingly for the patient. For example, you can choose between different socket modules and software upgrades – the choice is all yours. And even in the future, the latest upgrades and specific systems software for different countries will help you to you remain up-to-date with the newest electrosurgical technology. In spite of its wide choice of output and functions, operating the VIO 300 D is both simple and comfortable. It is individually configured to the needs of the specific operative procedure. Precise power output adjusted to the individual indication, the user-friendly VIO 300 D generator module functions as the central control unit, providing the right amount of power at the right time. Modern regulative technologies provide the optimal power dosages for the new and improved electrosurgical functions. CUT - You do the cutting – the VIO 300 D will automatically adjust the power output. Intelligent microprocessor technology will deliver the required minimal amount of power according to your current needs. The advantages of automatic power dosage: efficient operation with optimal results and the highest degree of safety; the ERBE Power Peak System takes specific features during the initial cutting stage into account and provides automatic support; improved cutting effects and reduced thermal damage to tissue; less stress for the patient. You can individually choose the most effective treatment option a unique ion of tried-and-tested or new electrosurgical modes for every medical specialty and every indication. Regulation of voltage and arcing in a single system for a superior cut. Depending on your choice of mode you will be able to utilize two different regulatory techniques provided by the VIO 300 D generator. ERBE voltage regulation constantly regulates the pre-ed voltages during the entire cutting process and automatically controls the power output creating reproducible cutting results which are largely independent of the cutting speed, type of electrode and tissue type. ERBE arcing regulation controls the intensity and size of the arcs required for the cut between the active electrode and the target tissue and constantly adjusts them. This means that the power output is controlled and optimized. Modes which are based on the regulation of arcing are particularly suitable for cuts carried out in adipose tissue or under water. COAG - The concept of the VIO electrosurgical generator is so variable that it offers all known types of monopolar and bipolar electrosurgical coagulation for all requirements and much more. the new SOFT coagulation to coagulation types which call for the simultaneous activation of two separate instruments. ERBE voltage regulation constantly maintains a pre-set voltage during the entire coagulation process. This ensures that the precise amount of power required is delivered. Even under widely differing conditions it is possible to create reproducible and optimal coagulation effects at all times. With a precisely limited or minimal power output adapted to individual requirements. If the procedure requires contact coagulation with minimal carbonization, Quick coagulation and as little sticking to the electrode as possible, then ERBE Soft Coagulation is the method of choice. The ERBE power regulation will maintain a constant preset power output level over a longer period, thereby creating an effective, previously unknown soft coagulation. Innovative development: the Neutral Electrode Safety System NESSY. With the NESSY safety concept and the ERBE patient plate NESSY Ω the VIO 300 D sets new standards for patient safety. Because of its new shape the NESSY Ω Neutral Electrode can be applied irrespective of direction. It practically precludes the troublesome œleading edge effect, i.e. the development of high current densities at the electrode edges.